BMW I01 Product Information page 87

High-voltage components
Table of Contents

Advertisement

I01￿High-voltage￿Components
5.￿High-voltage￿Battery￿Unit
High-voltage￿connection
Index
A
B
1
2
3
4
5
The￿high-voltage￿connection￿can￿be￿replaced￿as￿a￿separate￿component,￿just￿like￿all￿other￿components
of￿the￿high-voltage￿battery￿unit.
The￿diagnosis￿and￿repair￿of￿the￿high-voltage￿components￿is￿only￿allowed￿in￿a￿retail￿service
center￿that￿has￿qualified￿and￿certified￿service￿technicians.￿These￿technicians￿must￿have
completed￿the￿ST1403b￿I01￿High￿Voltage￿Battery￿and￿Maintenance￿instructor￿led￿course￿and
successfully￿passed￿the￿hands￿on￿certification.
Low-voltage￿connections
There￿are￿two￿low-voltage￿connections￿at￿the￿high-voltage￿battery￿unit￿of￿the￿I01:
1
Connection￿for￿lines￿to￿the￿SME￿control￿unit
2
Connection￿for￿the￿activation￿of￿the￿combined￿expansion￿and￿shutoff￿valve
The￿connection￿for￿the￿SME￿control￿unit￿has￿the￿following￿lines:
Voltage￿supply￿of￿the￿SME￿control￿unit￿with￿terminal￿30F￿and￿ground￿connection
Terminal￿30C￿for￿the￿voltage￿supply￿of￿the￿electromechanical￿switch￿contactors
Wake-up￿line￿from￿the￿BDC
Explanation
High-voltage￿connection￿with￿connected￿high-voltage￿cable
High-voltage￿connection￿with￿disconnected￿high-voltage￿cable
Bridge￿for￿high-voltage￿interlock￿loop￿(connected)
Mechanical￿slide
High-voltage￿connector￿of￿the￿high-voltage￿cable
Bridge￿for￿high-voltage￿interlock￿loop￿(disconnected)
High-voltage￿connection