I01High-voltageComponents
5.High-voltageBatteryUnit
High-voltageconnection
Index
A
B
1
2
3
4
5
Thehigh-voltageconnectioncanbereplacedasaseparatecomponent,justlikeallothercomponents
ofthehigh-voltagebatteryunit.
Thediagnosisandrepairofthehigh-voltagecomponentsisonlyallowedinaretailservice
centerthathasqualifiedandcertifiedservicetechnicians.Thesetechniciansmusthave
completedtheST1403bI01HighVoltageBatteryandMaintenanceinstructorledcourseand
successfullypassedthehandsoncertification.
Low-voltageconnections
Therearetwolow-voltageconnectionsatthehigh-voltagebatteryunitoftheI01:
1
ConnectionforlinestotheSMEcontrolunit
2
Connectionfortheactivationofthecombinedexpansionandshutoffvalve
TheconnectionfortheSMEcontrolunithasthefollowinglines:
•
VoltagesupplyoftheSMEcontrolunitwithterminal30Fandgroundconnection
•
Terminal30Cforthevoltagesupplyoftheelectromechanicalswitchcontactors
•
Wake-uplinefromtheBDC
Explanation
High-voltageconnectionwithconnectedhigh-voltagecable
High-voltageconnectionwithdisconnectedhigh-voltagecable
Bridgeforhigh-voltageinterlockloop(connected)
Mechanicalslide
High-voltageconnectorofthehigh-voltagecable
Bridgeforhigh-voltageinterlockloop(disconnected)
High-voltageconnection
81