I01High-voltageComponents
6.ChargingtheHigh-voltageBattery
Index
1
2
3
4
5
6
7
8
9
ThechargingsocketinthevehicleforcombochargingincludesthesocketsforACchargingandthe
socketforDCcharging.Theadvantageofthischargingsocketconfigurationisthatthecustomercan
usebothACchargingstationsandDCchargingstationsforchargingthehigh-voltagebattery.
DuringDCcharginganelectricarcmayformbydisconnectingthechargingplugduringthecharging
procedure.Topreventthisthechargingplugislockedelectromechanicallyduringthecharging
procedure.Thiswayapossibledangeroussituationfortheuserisavoided.Anergonomichandleat
thechargingplugandlowconnectionanddisconnectionforcesenablecomfortableoperationofthe
connectorusingonlyonehand.
SimultaneouschargingviaACandDCisnotpossible.
6.4.3.LIM
ThemaintasksoftheLIMarealreadydescribedpreviouslyinthischapter.Onlytheadditional
functionsandtasksoftheLIMforcombochargingaredescribedhere.AnewtasksoftheLIMis,for
example,theactivationoftheswitchcontactorsintheKLEforDCcharging.
Communication
AlsoforcombochargingtheLIMassumesthecommunicationbetweenthevehicleandthecharging
station.Thecommunicationbetweenthevehicleandthechargingstationisenabledandthecharging
procedureiscontrolledviathepilotandproximityline.
Usingtheproximitylinethecorrectconnectionofthechargingcableatthevehicleisidentifiedandthe
maximumcurrentcarryingcapacityofthechargingcableismeasuredbytheLIMusingtheresistorin
thechargingcable.
Thehigh-voltagepowermanagementintheEMEsendsarequesttochargethehigh-voltagebattery
totheLIMviathePT-CAN.TheLIMthenstartsthecommunicationwiththechargingstationviathe
pilotline.Theinformationaboutchargingrequirement,chargingrangeandaccuracyisexchanged.
OnlyaftersuccessfulcommunicationstartisthechargingvoltageappliedtothephaseL1ortothe
DCpositivewireandgroundcable.ThisalsogivesfurtherprotectionforcustomersandService
employeesagainstthedangersofelectricity.
TheLIMsendsasignalfor"Enablecharging"forACchargingviatheseparatelinetoEMEandKLE.
ActivationoftheswitchcontactorsintheKLE
126
Explanation
Connectionforproximityline
ConnectionforphaseL1
Connectionforprotectiveearth(PE)
Connectionforneutralconductor(N)
Connectionforpilotline
ProtectivecapforACchargingsocket
ProtectivecapforDCchargingsocket
ConnectionforDCgroundcable
ConnectionforDCpositivewire