I01High-voltageComponents
6.ChargingtheHigh-voltageBattery
AlthoughACchargingwith3.7 kWisstandardequipmentinmanycountriesintheUSmarket,itonly
referstothechargingviatheoccasionalusecable(insertedintoanormal110Vsocket).Thebig
advantageofthischargingoptionisthatforchargingthehigh-voltagebatterythechargingcablecan
beconnectedatanyhouseholdpowersocketwithprotectivecontact.However,thecurrentlevelfor
chargingisalsorestrictedtoamaximum16A.Themaximumchargingpoweris,forexampleforsupply
atACvoltagenetworkinGermany,3680 W(P=UxI=230 Vx16 A).Thetotaltimeittakestofully
chargeadischargedhigh-voltagebatteryoftheI01(storableenergy:18.8 kWnet)wouldbeabout7
hours.Inordertoreducetheuseofthemaximumchargingpowerforhouses,achargingprocedureis
neverperformedatmaximumchargecurrent.Therefore,theactualchargingtimeislonger.
TheEMEisdesignedsoitcanprovideamaximumelectricalpowerof3.7 kWontheoutput
side.Thisischargingconfigurationisused(intheUSmarket)onlywhenchargingwiththe
occasionalusecableviaahousehold120Vsocket.AnditsufficienttofullychargetheI01
high-voltagebatteryunderoptimalmarginalconditionsinabout16hours.
98