I01High-voltageComponents
2.ImportantNotes
Thefollowinggraphicshowsthedesignoftheroundhigh-voltageconnectoronthehigh-voltage
cable.
Designoftheroundhigh-voltageconnector
Index
1
2
3
4
5
6
7
8
9
10
Thebridgeinthehigh-voltageconnectorservesforelectricalsafety.Thesignalofthehigh-voltage
interlocklooprunsoverthisbridgewhenthehigh-voltagecableisconnectedtothehigh-voltage
component.Fortheconnectionofthehigh-voltagecabletotheEKKandtotheelectricheatingthe
voltagesupplyoftheEKKortransmissioncontrolunitrunsviathebridge.Ifoneofthecircuitsis
interrupted,thisalsoresultsinanautomaticinterruptiontothecurrentflow(returnstozero)inthe
respectivehigh-voltagecable.Asthetwocontactsofthebridgeoppositethehigh-voltagecontacts
advance,thismeasureconstitutesprotectionagainsttheformationofanelectricarcwhenremoving
thehigh-voltageconnector.
2.4.Connectionsforpotentialcompensationlines
Thesafetyconceptofthehigh-voltagesystemincludesthemeasurementandmonitoringofthe
isolationresistanceofthehigh-voltagecablestoeachotherandagainstground.Thissafetyfunction
isperformedintheI01oftheSMEcontrolunit,butshouldidentifyisolationfaultsintheentirehigh-
voltagecircuit.Forthispurpose,thehousingofallhigh-voltagecomponentsmustbeconnected
galvanicallytoground.
12
Explanation
High-voltagecable
Actuationpointsonlockingelements
Housing
Lockingelement
Connection1forbridgeintheconnector
Connectionforshielding
High-voltageconnection,pin 2(DC,minus)
Mechanicalencoding
Connection2forbridgeintheconnector
High-voltageconnection,pin 1(DC,plus)