I01High-voltageComponents
10.REME
•
Low-voltageconnections
•
High-voltageconnections
•
Connectionforpotentialcompensationline
•
Connectionsforcoolantlines.
10.3.1.Low-voltageconnections
Inthemultipolarlow-voltageconnectorattherangeextenderelectricalmachineelectronicstwomulti-
corelineswiththefollowingsignalsarecombined:
•
VoltagesupplyfortheREMEcontrolunit(terminal30Bandgroundconnection)
•
PT-CAN2
•
TwolinesfromtheACSMforthesignalforthequickshutdownofthehigh-voltagesystemin
theeventofanaccidentofcorrespondingseverity
•
Wake-upline
•
Inputandoutputofthecircuitofthehigh-voltageinterlockloop(REMEcontrolunitdoesnot
evaluatethesignal)
•
Rotorpositionsensoroftheelectricalmachine(supplyandsensorsignals)
•
Signalofthetemperaturesensorinthestatorcoilsoftheelectricalmachine.
Theselinesandsignalshaverelativelylowcurrentlevels.
10.3.2.High-voltageconnections
Twohigh-voltagecablesareconnectedattheREME:
•
3-phasehigh-voltagecablefromtherangeextenderelectricalmachine
•
Two-pinhigh-voltagecablefromtheKLE.
155