I01High-voltageComponents
2.ImportantNotes
Electricalconnectionsattheelectricheating
Index
1
2
3
Thehigh-voltagesystemmustnotbeoperatedifthepotentialcompensationcablesarenotproperly
connectedtothehigh-voltagecomponents.
Ifintheeventofarepairthehigh-voltagecomponentsorthepotentialcompensationlinesare
replaced,thefollowingmustbeobservedduringassembly:Thegalvanicconnectionbetweenthe
housingofthehigh-voltagecomponentsandgroundmustbeproperlyre-established.Therepair
instructionsmustbestrictlyobserved(tighteningtorque,self-cuttingscrews).Inaddition,asecond
Serviceemployeehastochecktherepairwork(correcttighteningtorqueandcorrectlocationofbare
metal)andrecordthisinwritingintherepairorder.
Explanation
Potentialcompensationline
Housingoftheelectricheating
High-voltageconnector
13