Table 30: Information About Existing Module Diagnostics; Table 31: Information About Existing Channel Diagnostics - WAGO 767-5803 Manual

8dio 24v dc 0,5a (8xm12) digital input/output module dc 24 v, 0,5 a for wago-speedway 767 series
Table of Contents

Advertisement

56
Parameterizing
Pos : 30.9 /Serie 767 (WAGO-SPEED WAY)/Par ametrieren/I/O-M odule/Parametri erung 767- 4801, - 02, -05, -06, 58xx, 7401 Globale Diagnos en @ 7\mod_1265877071562_21.doc x @ 50302 @ @ 1

Table 30: Information about existing module diagnostics

Global Diagnostics
Diagnostics
Low voltage of U
Low voltage of U
Pos : 30.10 /Serie 767 ( WAGO-SPEED WAY)/Parametrier en/I/O-Module/Parametrier ung Global e Di agnosen Kurzschl uss /Überlas t und U nterbr echung Fel dversorgung @ 8\mod_1278394655719_21.doc x @ 59061 @ @ 1
Short circuit/ overload
encoder supply
Pos : 30.11 /Serie 767 ( WAGO-SPEED WAY)/Parametrier en/I/O-Module/Parametrier ung Kanaldi agnosen Ü bertemper atur @ 7\mod_1268294869501_21.doc x @ 52378 @ @ 1

Table 31: Information about existing channel diagnostics

Channel Diagnostics
Diagnostics
Overtemperature
Pos : 30.12 /Serie 767 ( WAGO-SPEED WAY)/Wichtige Erläuter ung en/Sic herheits hinweise/Hinweis/Hi nweis : U nterbrechung S-BU S 48er @ 8\mod_1278393489593_21.doc x @ 59044 @ @ 1
Interruption of the S-BUS
If there is an interruption of the S-BUS, the module is automatically put in STOP
mode. The module outputs are disabled.
Pos : 30.13 /D okumentati on allgemei n/Gli ederungsel emente/---Seitenwec hs el--- @ 3\mod_1221108045078_0.doc x @ 21810 @ @ 1
Description
LS
If an undervoltage of the logic and sensor supply U
on the module, the outputs are disabled and a corresponding diagnostic
is transmitted to the fieldbus coupler. The F-LED of the module
illuminates.
LS
If an undervoltage of the actuator supply U
module, the outputs are disabled and a corresponding diagnostic
transmitted to the fieldbus coupler. The module F-LED illuminates.
The module has detected a short circuit or overload of the encoder
supply (only possible when field supply is switched on).
Description
The module has identified overheating on the corresponding channel
(1 – 8) (only enabled when the actuator output is switched on).
767-5803 8DIO 24V DC 0,5A (8xM12)
Disabling the outputs.
If there is an undervoltage of U
module outputs are disabled. Machine components can
be placed in a dangerous condition, as well as
personnel and machine put in danger.
Disabling the outputs.
If there is an undervoltage of U
module outputs are disabled. Machine components can
be placed in a dangerous condition, as well as
personnel and machine put in danger.
WAGO-SPEEDWAY 767
and/or U
, the
A
LS
of < 18 V occurs
LS
and/or U
, the
A
LS
of < 18 V occurs on the
A
Manual
Version 1.1.0