System Data, Connection Values, Dimensions And Weight - Siemens SIMOTION D410 Manual

Hide thumbs Also See for SIMOTION D410:
Table of Contents

Advertisement

Circuit-diagram macros
EPLAN circuit-diagram macros are available for SIMOTION D410. The macros are supported
when you create circuit diagrams.
For information on how to do this, refer to: Internet address
support.automation.siemens.com/WW/view/en/31622426).
7.4

System data, connection values, dimensions and weight

PLC and motion control performance
Table 7-1
Maximum number of axes
Minimum PROFIBUS cycle clock
Minimum PROFINET send cycle clock
Minimum position control/interpolator cycle
clock
Table 7-2
Max. number of axes for integrated drive
control (servo/vector/
Memory
Table 7-3
RAM (Random Access Memory)
RAM disk (load memory)
Retentive memory
Persistent memory
(user data on CF card)
Non-volatile data backup
Backup time, min.
Real-time clock, min.
Table 7-4
Diagnostic buffer (non-volatile)
SIMOTION D410
Manual, 04/2014
7.4 System data, connection values, dimensions and weight
General information about SIMOTION D410
Integrated drive control
V / f )
Memory data
Memory for system data and its memory size
(http://
1 (real axis)
2 ms (D410 DP)
0,5 ms (D410 PN)
2,0 ms
1 / 1 / 1 (alternative)
drive control based on SINAMICS S120 CU310, firmware
version V2.x
38 MB (as of V4.2)
26 MB
(A 20 MB RAM is available for java applications with V4.1
SP2 and higher.)
23 Mbyte (as of V4.3)
17 Mbytes
9 KB
1-GB CF: 300 MB
Unlimited (maintenance-free backup)
5 days (maintenance-free backup)
100 messages (SIMOTION)
100 messages (SINAMICS Integrated)
Technical data
87