Interface characteristics
Table 4-12
Characteristic
Encoder interface
Connector type
Encoder power supply
Limit frequency
SSI baud rate
Resolution absolute position SSI
Max. cable lengths
● For TTL incremental encoder
● For HTL incremental encoder
● For SSI absolute encoder
1)
2)
NOTICE
Destruction of the encoder electronics
Operation of a 5 V encoder on the 24 V encoder supply may result in the destruction of its
electronic components!
Make sure that you can operate the connected encoder on a 24 V power supply (e.g. HTL
encoder). This setting can be set in the expert list of the drive in parameter p0400 and in the
following parameters.
SIMOTION D410
Manual, 04/2014
Interface X23
As of a cable length of 200 m, use a power supply cable with a cable cross-section ≥ 0.75 mm²!
Signal cables twisted in pairs and shielded.
4.6 Encoder interface (HTL/TTL/SSI)
Type
● TTL or HTL incremental encoders (with
adjustable parameters)
● Absolute encoder SSI
15-pin SUB-D connector
24 V DC/0.35 A or 5 V DC/0.35 A
500 kHz
100 . . .250 kBaud
30 bits
● 100 m (bipolar signals only)
● 100 m (for unipolar signals)
● 300 m (for bipolar signals)
● 100 m
Interfaces
2)
1) 2)
53