Siemens SIMOTION D410 Manual page 88

Hide thumbs Also See for SIMOTION D410:
Table of Contents

Advertisement

Technical data
7.4 System data, connection values, dimensions and weight
Communication
Table 7-5
DRIVE-CLiQ interface
PROFIBUS interface
PROFINET interface
Table 7-6
Address space
Logical I/O address space
Physical I/O address space
● PROFIBUS: max. each for inputs and
● PROFINET: max. each for inputs and
Permanent process image for
BackgroundTask (I/O variables)
Additional configurable process image for
each cyclic task (I/O variables)
Address space for each PROFIBUS DP
station
Address space per SINAMICS Integrated
(PROFIBUS Integrated)
Address space for each PROFINET device 1400 Byte
General technical data
The SIMOTION D410 has an integrated fan.
Table 7-7
Power supply
Current consumption, typically
Inrush current
Power loss, typ.
1)
88
SIMOTION D410 interfaces
Address space
outputs
outputs
SIMOTION D410 electrical connection values
With no load on inputs/outputs, no 24 V supply via DRIVE‑CLiQ and PROFIBUS interface
1
1 (D410 DP only)
● Isochronous
● Can be configured as master or slave
1 interface with 2 ports (D410 PN only)
● Supports PROFINET IO with IRT and RT
● Can be configured as PROFINET IO controller and/or
device
D410
8 KB
1 KB (D410 DP)
1 KB (D410 PN)
64 bytes
Yes
244 Byte
512 Byte
24 V DC (permissible range: 20,4 ... 28.8 V)
Basic configuration
1)
0.8 A
3,0 A
20 W
SIMOTION D410
Manual, 04/2014

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion d410 dpSimotion d410 pn