4.8 Power supply
● For commissioning/diagnostics with deactivated Power Module supply voltage
● If the SIMOTION D410 is snapped on to a mounting plate and not on to a PM340 Power
Interface characteristics
Table 4-17
Features
Connector type
Connectable cable types and conductor cross-
sections
Stripped length
Tool
Tightening torque
Max. current carrying capacity, incl. loop-through
Max. cable length
58
Module
Note
A control DC power supply is required to operate a motor with an integrated holding brake.
A 24 V connection supplies the voltage (X124). Take note of the motor holding brake
voltage tolerances and the connecting cable voltage drop.
Set the DC power supply to 26 V. This can ensure that the motor holding brake supply
voltage is in the permissible range if the following boundary conditions are fulfilled:
● You are using a Siemens AC motor.
● You are using Siemens Motion-Connect power cables.
● The motor cables are no longer than 100 m.
Interface X124
Rigid
Flexible
Flexible, with wire-end ferrule without plastic
sleeve
Flexible, with wire-end ferrule with plastic
sleeve
AWG / kcmil
Type
4-way screw-type terminal
0.2 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm²
0.2 mm² ... 1.5 mm²
22 ... 12
6 ... 7 mm
Screwdriver 0.5 x 3 mm (M2.5)
0.4 to 0.5 Nm
20 A (15 A per UL/CSA)
10 m