Safety instructions

1.2 Specific safety information for SIMOTION D410

For more information about residual risks of the components in a drive system, see the relevant
sections in the technical user documentation.
1.2
Specific safety information for SIMOTION D410
Danger to life from hazardous voltage when connecting an unsuitable power supply
Only safety extra low voltage in accordance with EN/IEC 60950-1 may be connected at all
connectors and terminals.
Danger to life from unexpected movement of machines on automatic restart
An automatic restart can be programmed for SIMOTION controllers. When the power returns,
the axes start automatically.
Make sure this presents no hazard to personnel or property.
NOTICE
Damage to the CompactFlash card from electrical fields or electrostatic discharge
The CompactFlash card is an ESD-sensitive component.
De-energize the SIMOTION D410 device before inserting or removing the CompactFlash
card. The SIMOTION D410 is in a de-energized state when all the LEDs are OFF.
Comply with the ESD rules.
NOTICE
Overheating if ventilation clearances are too small
Insufficient ventilation clearances result in overheating and therefore in more failures and a
shortened life of systems / devices.
Make sure the ventilation clearances of 50 mm are provided above and below the
components. The ventilation openings may not be covered by connecting cables.
18
WARNING
WARNING
SIMOTION D410
Manual, 04/2014