Cua31/Cua32 Control Unit Adapter - Siemens SIMOTION D410-2 Manual

Hide thumbs Also See for SIMOTION D410-2:
Table of Contents

Advertisement

Additional references
Detailed information about the TM15 and TM17 High Feature can be found in the
Terminal Modules TM15 / TM17 High Feature
6.6

CUA31/CUA32 control unit adapter

Properties
You can connect a blocksize power module to the DRIVE-CLiQ interface using the CUA31
adapter module. The CUA32 adapter module also provides an encoder interface for an HTL,
TTL or SSI encoder.
Interfaces
Table 6- 5
Interface
DRIVE-CLiQ interface
EP terminals/temperature sensor connection
Power Module Interface (PM-IF)
24 V electronic power supply
Encoder interface (HTL, TTL, SSI)
Only SSI encoders without incremental tracks may be
operated.
Maximum DRIVE-CLiQ cable length
1)
The 50 mm clearances above and below the component must be observed. The ventilation
openings may not be covered by connecting cables.
Additional references
You will find more information on the CUA31/CUA32 control unit adapter in the
SINAMICS S120 AC Drive
SIMOTION D410-2
Manual, 02/2012
Overview of the interfaces for the adapter modules
CUA31 with order number 6SL3040-0PA00-0AAx (x ≥ 1 required)
CAUTION
Commissioning Manual.
Manual.
Spare parts / accessories
6.6 CUA31/CUA32 control unit adapter
CUA31
CUA32
1)
3
3
1
1
1
1
1
1
0
1
100 m
100 m
SIMOTION
81