Siemens SIMOTION D410 Manual page 94

Hide thumbs Also See for SIMOTION D410:
Table of Contents

Advertisement

Technical data
7.8 Mechanical and climatic ambient conditions
Climatic ambient conditions
SIMOTION D410 may not be used under the following climatic ambient conditions:
Note
Observe the application ranges of the PM340 power modules along with their derating. For
further information, see SINAMICS documentation.
Table 7-18
Climatic ambient conditions
Ambient conditions
Permissible ambient
temperature for operation
Maximum installation
altitude
Relative humidity
Air pressure
Pollution degree
Pollutant concentrations
94
Application range
0 to +55 °C
2000 m to max. 5000 m above sea level
5 to 95 %
795 to 1080 hPa
2 acc. to EN 60664-1
Substances:
SO
: <0.5 ppm;
2
Relative humidity <60 %, no condensation
H
S: <0.1 ppm;
2
Relative humidity <60 %, no condensation
Remarks
Oil mist, ice formation, moisture condensation,
dripping water, spraying water, splashing water
and water jets are not permitted (EN 60204, Part
1)
From an altitude of 2000 m, the maximum
ambient temperature decreases by 7°C every
1000 m.
Without condensation, corresponds to a relative
humidity (RH) severity level 2 according to
IEC 1131‑2
-
-
Test:
10 ppm 4 days
1 ppm; 4 days
SIMOTION D410
Manual, 04/2014

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion d410 dpSimotion d410 pn

Table of Contents