Siemens SIMOTION D410 Manual page 56

Hide thumbs Also See for SIMOTION D410:
Table of Contents

Advertisement

Interfaces
4.7 EP terminals/temperature sensor connection
For more information on "thermal motor protection", see the
Manual.
Note
For SIMOTION D410, the following safety functions are available with version V4.1 SP2 and
higher:
● Safety Integrated Basic Functions via the EP terminals
● Safety Integrated Extended Functions with TM54F
● Safety Integrated Extended Functions via secure communication from "PROFIsafe to
For further information on Safety Integrated, see the
Function Manual .
Interface characteristics
Table 4-15
Characteristic
Connector type
Grid
Maximum connectable cross-section
Interface assignments
Table 4-16
Interface assignment X120
Representation
This is the second temperature channel (T2), which depending on the parameterization, is used as a single channel or in
1)
combination with the first temperature channel (T1, see X23).
The EP terminals must be wired on the Power Module on chassis units.
2)
56
PROFIBUS"
Control (F logic) is via a SIMATIC F-CPU which is connected to PROFIsafe via
PROFIBUS (e.g. a CPU 317F-2 DP)
Interface X120
Pin
Name
1
Reserved, do not use
2
Reserved, do not use
3
G
4
+ Temp
1)
5
- Temp
1)
6
Reserved, do not use
7
EP +24 V
8
EP M1
2)
Type
Mini Combicon, 8-pin
2.5 mm
1.5 mm
Description
Ground
KTY or PTC input
Ground for KTY or PTC
Safety Integrated Basic Functions (+)
2)
Safety Integrated Basic Functions (-)
SINAMICS S120 Commissioning
SINAMICS S120 Safety Integrated
2
SIMOTION D410
Manual, 04/2014

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion d410 dpSimotion d410 pn

Table of Contents