Connecting
6.11 Connecting an external encoder
Procedure for connecting encoders
To connect an external encoder (HTL, TTL or SSI encoder), proceed as follows:
1. Connect the connecting cable to the encoder.
2. Plug the D-Sub connector (15-pin) to the socket X23.
3. Lock the connector using the finger screws.
NOTICE
Destruction of the encoder electronics
Operation of a 5 V encoder on the 24 V encoder supply may result in the destruction of its
electronic components!
Make sure that you can operate the connected encoder on a 24 V power supply (e.g. HTL
encoder). This setting can be set in the expert list of the drive in parameter p0400 and in the
following parameters.