1.3 General Safety
Only qualified personnel shall install, operate, and service the power system and components.
Installation instructions provided with each unit.
Observe all applicable national and local electrical and building codes during installation.
Maintain the security of all SELV circuits in the system when connecting to other equipment like signaling/
alarm circuits, emergency power off (EPO) circuits, relay contacts, Ethernet or CANbus. The other equip-
ment must be the same circuit type.
Bolt the AMPS HP2 system securely to the floor.
Always assume electrical connections and/or conductors are live.
Turn off all circuit breakers and double-check potentially charged components with a voltmeter before per-
forming installation or maintenance.
Before installation, verify that the input voltage and current requirements of the load are within the specifica-
tions of the power system. Refer to the product nameplate label.
Keep tools away from walk areas to prevent personnel from tripping over the tools.
Wear safety glasses when working under any conditions that may be hazardous to your eyes.
Do not work on the power system, or connect or disconnect cables, during atmospheric lightning activity.
Do not let water enter the enclosure as this can cause electrical shorts, shocks, or electrocutions.
Do not remove the covers of electrical components as this can cause electrical shorts, shocks or electrocu-
tions. There are no user serviceable parts inside.
The power system is certified for use in restricted access locations only.
All operators must be trained to perform the emergency shutdown procedure.
The power system must be connected only to a dedicated branch circuit.
Equip the utility service panel with a circuit breaker of appropriate rating.
Do not exceed the output rating of the system when connecting the load.
External metal surface temperatures on the rear of the AMPS HP2 system can exceed 70°C, do not touch.
Use caution when working around the equipment while it is in operation.
Always use proper lifting techniques when handling units, modules, or batteries.
The power system contains more than one live circuit. Voltage may still be present at the output even when
the input voltage is disconnected.
Minimize the risk of sparks and wear on the connectors. Always switch off the inverter's battery circuit
breaker before connecting or disconnecting the batteries.
In the event of a short-circuit, batteries present a risk of electrical shock and burns from high currents. Ob-
serve proper safety precautions.
Always wear protective clothing, such as insulated gloves, and safety glasses or a face shield when working
with batteries.
Carry a supply of water, such as a water jug, to wash eyes or skin in case of exposure to battery electrolyte.
Do not allow live battery wires to contact the enclosure chassis. Shorting battery wires can result in a fire or
possible explosion.
Replace batteries with those of an identical type and rating. Never install old or untested batteries.
Only use insulated tools when handling batteries or working inside the enclosure.