Command
Description
INR 1 <value>
Initiates an enhanced interrogator
Examples
Initiate an interrogator:
(INR 1)
Initiate an interrogator to run a basic report excluding warp files:
(INR 1)
or
(INR 1 0)
Initiate an interrogator to run an enhanced report including warp files (results in larger report file size):
(INR 1 1)
Initiate an interrogator to run an enhanced report excluding warp and LOS files:
(INR 1 2)
Initiate an interrogator to run an enhanced report including all warp and LOS files (results in larger report file
size):
(INR 1 255)
LHO–Lens Horizontal Position Adjustment
Adjusts the lens offset to a specific horizontal position with a specified direction.
In most cases the active lens is specified by the current channel. If a user selects a different lens file
in the ILS File Setup panel of the user interface, the selected lens file becomes active. This file may be
different from the one specified by the current channel.
Parameters
•
Access level: Operator
•
Power level (minimum): Power Up
Commands
Command
Description
LHO <position>
Moves the lens mount to a specified horizontal position
with a specified direction.
LHO+STRT
Starts the motor moving in a specified direction.
CineLife+ Technical Reference–Serial Commands
020-103075-05 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
CineLife+
Values
1 0 = Initiates basic interrogator (same as INR 1)
1 1 = Includes warp files
1 2 = Excludes warp and LOS files
1 255 = Includes all warp and LOS files
Values
position = Numeric value
-1 = Negative approach
1 = Positive approach
™
serial commands
16