Specifications
Environmental specifications
Specification
Temperature range
Operating
Nonoperating
Relative humidity
(noncondensing)
Operating
Nonoperating
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per
1000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed.
Mechanical specifications
Specification
Height
Depth
Width
Weight (approximate values)
Server, minimum
Server, maximum
Server with storage expansion unit, minimum
Server with storage expansion unit, maximum
Server and the wall mount
Value
—
10°C to 35°C (50°F to 95°F)
-30°C to 65°C (-22°F to 149°F)
—
Maximum wet bulb temperature of 28°C
(82.4°F) = 10% to 90%
Maximum wet bulb temperature of 38.7°C
(101.7°F) = 0% to 95%
Value
4.95 cm (1.95 in)
25.40 cm (10.00 in)
25.40 cm (10.00 in)
—
1.55 kg (3.42 lb)
3.69 kg (8.13 lb)
4.09 kg (9.02 lb)
8.92 kg (19.67 lb)
5.89 kg (12.99 lb)
Specifications 63