Banner D10 Expert Manual

Banner D10 Expert Manual

Dual discrete outputs, advanced sensor for use with plastic fiber optics
Hide thumbs Also See for D10 Expert:

Advertisement

Red Beam
D10DNFP
D10DNFPQ
D10DPFP
D10DPFPQ
* 9 m (30
) cables are available by adding suffix "W/30" to the model number of any cabled sensor (e.g., D10DNFP W/30 ).
'
A model with a QD connector requires a mating cable (see page 14).
WARNING . . .
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications.
A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety
Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
Printed in USA
D10 Expert
Advanced sensor for use with plastic fiber optics
Easy-to-set automatic
single-point programming plus manual adjustment for fine-tuning
16-bit microcontroller and 12-bit Analog-to-Digital converter for high-performance,
low-contrast sensing
Easy-to-read 4-digit display for TEACH and signal strength readout, plus indicators
for a continuous readout of operating status (user configurable)
Two discrete outputs, PNP or NPN
Four-mode power and speed selection with automatic cross-talk avoidance circuitry
Selectable OFF-delay options
Gate input wire can be used to selectively inhibit sensor outputs from switching
Models available with visible red (680 nm) or visible green (525 nm) sensing beam
Models available with 2 m or 9 m (6.5' or 30') cable or integral Pico-style
quick-disconnect
Sleek, ultra-slim 10 mm housing, mounts to a standard 35 mm DIN rail
* U.S. Patent #5,808,296
Models
Green Beam
D10DNFPG
D10DNFPGQ
D10DPFPG
D10DPFPGQ
Not To Be Used for Personnel Protection
Dual Discrete Outputs
Features
Expert-style TEACH options* including static, dynamic, and
Models
Cables*
2 m (6.5') Cable
6-pin Pico-style QD
2 m (6.5') Cable
6-pin Pico-style QD
03/09
Discrete Outputs
NPN
PNP
P/N 64154 rev. F

Advertisement

Table of Contents
loading

Summary of Contents for Banner D10 Expert

  • Page 1 These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
  • Page 2 • Discrete: switchpoint positioned at middle of range • Raw signal value (1234) * Diffuse mode performance based on 90% reflectance white test card. ** ø0.010" bifurcated fiber not recommended in these speed settings. Contact Banner Applications for more information. † See note on page 10. Banner Engineering Corp. Minneapolis, MN U.S.A.
  • Page 3: Sensor Programming

    D10 Expert Dual Discrete Outputs ™ Sensor Programming Programming Procedures Two push buttons, Dynamic (+) and Static (-), may be used to access and set programming parameters. For remote programming, connect a switch or digital input to the gray wire; length of the individual pulses is equal to the value T: 0.04 seconds ≤...
  • Page 4 D10 Expert Dual Discrete Outputs ™ Two-Point Static TEACH (Threshold) 2nd Taught 1st Taught Condition Condition • Establishes a single switching threshold Sensor positions threshold midway • Threshold position is adjustable using “+” and “-” buttons (see Manual Adjust, page 9) between taught conditions Static TEACH is the traditional setup method, used when two conditions can be presented Output OFF Output ON by the user.
  • Page 5 D10 Expert Dual Discrete Outputs Output OFF Output ON ™ Darkest Position Most Light (no signal) adjusted by (saturated Manual Adjust signal) Dynamic TEACH and Adaptive Thresholds Darkest Taught Lightest Taught Condition Condition Sensor positions • TEACH on-the-fly.
  • Page 6 D10 Expert Dual Discrete Outputs ™ Single-Point Window SET Sensing window size adjusted by Manual Adjust Sensor positions window thresholds • S ets a single ON condition that extends 200 counts above and below the taught condition ± 100 counts from the presented condition (including ±100 counts hysteresis) Hysteresis Hysteresis • All other conditions (lighter or darker) result in OFF output...
  • Page 7 Sensor positions window thresholds ≈10% from the presented condition D10 Expert Dual Discrete Outputs ™ Output OFF Output ON Output OFF Darkest Condition Most Light (no signal) Presented (saturated signal) Single-Point Light SET Threshold position adjusted by Manual Adjust • S ets a threshold slightly below the taught condition (see Figure 7) Sensor positions • A ny condition darker than the threshold condition causes the output to change state...
  • Page 8 Sensor positions threshold slightly below the presented condition D10 Expert Dual Discrete Outputs Output ON Output OFF ™ Darkest Condition Most Light Presented (no signal) (saturated signal) Single-Point Dark SET Threshold position adjusted by Manual Adjust • S ets a threshold slightly above the taught condition (see figure 9). • A ny condition lighter than the threshold condition causes the output to change state.
  • Page 9: Manual Adjust

    D10 Expert Dual Discrete Outputs ™ Manual Adjust Manual Adjust is used during RUN mode and is accomplished via the push buttons only. Its behavior depends on whether a switching threshold or a sensing window is used. Switching Threshold: • Fine-tunes sensing sensitivity • Press “+” to increase; press “-” to decrease...
  • Page 10: Sensor Setup

    D10 Expert Dual Discrete Outputs ™ Sensor Setup • Configures sensor display and operating parameters. • Click Dynamic (+) or double-pulse remote line to select an option. • Changes are updated instantly. • Click Static (-) or single-pulse remote line to advance. Remote Push Button Result 0.04 sec. ≤ T ≤ 0.8 sec. • Press and hold • Double-pulse the • Indicator Arrow Icon 1 ON Red both buttons remote line. concurrently for > 2 seconds. Light Operate: • Click Dynamic (+) to • Double-pulse remote toggle between line to toggle between • Display flashes “lo”...
  • Page 11: Advanced Setup

    D10 Expert Dual Discrete Outputs ™ Advanced Setup • Advanced adjustments to previously configured sensor display and operating parameters. • Quad-click Static (-) or quad-pulse remote line before exiting “Power and Speed” settings to enter this mode. • Click Dynamic (+) or double-pulse remote line to select an option. • Click Static or single-pulse remote line to advance. • Changes are updated instantly. Remote Push Button Result 0.04 sec. ≤ T ≤ 0.8 sec. • From “Power • From “Power • I ndicator Arrow Icons and Speed” and Speed” mode, 1 and 2 remain red mode, quad-click quad-click the • D isplay shows...
  • Page 12: Gate Input

    In the unlikely event that the setup parameters are lost or become corrupt, the display will continuously scroll: “USEr PSF Error.” Reteach the sensor to recover. If the problem persists, contact your Banner representative for further information. Gate Input The pink wire is configured as a gate input. When this wire is pulled low (i.e., to the sensor ground;...
  • Page 13 D10 Expert Dual Discrete Outputs ™ Dimensions 10.5 ± 0.2 mm (typ.) (0.41") Slides Up to Release Fibers 7.6 mm 35.9 mm 0.30" Plastic Fiber (1.41") Emitter Port Plastic Fiber Receiver Port 9.8 mm Mounting Bracket (0.39") (included) 61.3 mm (2.42")
  • Page 14 D10 Expert Dual Discrete Outputs ™ Hookups NPN Output Models PNP Output Models – 12-24V dc 12-24V dc – Load Load Load Load Teach Teach Gate Gate NOTE: QD hookups are functionally identical. Accessories Pico-Style Quick-Disconnect Cables PUR jacket, polyurethane connector body, POM snap-lock coupling...
  • Page 15 D10 Expert Dual Discrete Outputs ™ Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 P/N 64154 rev. F...
  • Page 16 Banner products. This warranty is in lieu of any other warranty either expressed or implied. P/N 64154 rev. F Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com...

Table of Contents