L-GAGE
LTF Time of Flight Laser Distance Sensor with IO-Link
5 Additional Remote TEACH Procedures
5.1 TEACH Both Discrete Output Switch Points Together
Use the following procedure to teach both Discrete Output switch points at the same time using the remote input. This
feature is not available using the buttons.
1. Access the TEACH mode.
Action
Single-pulse the remote input.
2. Present the target.
Action
Present the switch point one target.
3. TEACH the sensor.
Action
Three-pulse the remote input.
4. Present the target.
Action
Present the switch point two target.
5. TEACH the sensor.
Action
Single-pulse the remote input.
5.2 TEACH Both Discrete Output Midpoints Together
Use the following procedure to teach an identical discrete output midpoint (switch point) for both D1_OUT and D2_OUT at
the same time using the remote input. This feature is not available using the buttons. Note that if the window sizes and/or
offsets were set independently (using the buttons), the windows taught using the following procedure could be different.
When the Discrete Output is set to Switch Mode, the SPt TEACH is executed with SPtRef=Custom and Offset=0 mm.
28
T
T
T
www.bannerengineering.com - Tel: + 1 888 373 6767
Result
"RMT TCH" and the current measurement
value display.
Result
"RMT TCH"and the target's measurement
value display.
Result
"D1D2Spt1 Teaching" displays while the
sensor is being taught.
TEACH Accepted
The new value displays on the second line
T
T
of the display, flashes, and then
"D1D2Spt2" and the current measurement
T
value display.
TEACH Not Accepted
"FAIL" flashes, the sensor returns to step 2,
and "RMT TCH" displays.
Result
"D1D2Spt2" and the target's measurement
value display.
Result
"D1D2Spt2 Teaching" displays while the
sensor is being taught.
TEACH Accepted
The new value displays on the second line
T
of the display, flashes, and the sensor
returns to Run mode.
TEACH Not Accepted
"FAIL" flashes, the sensor returns to step 2,
and "RMT TCH" displays.