Note the following properties of the digital outputs:
● The outputs are only changed once when the event occurs.
The outputs remain set unchanged even when the event is no longer pending.
● Pending events have no effect on the output.
● If an output is changed when an antenna error is detected, this output nevertheless
remains unchanged when the antenna error is eliminated
7.3.7

The "Settings - Communication" menu item

The "Settings - Communication" menu item is divided into three tabs.
● Network interfaces
● XML
● OPC UA
In the "Network interfaces" tab, you can enable/disable the network ports
(RF680R/RF685R), SNMP and NTP protocols . In the "XML" tab, you can specify which data
is sent via the XML interface. In the "OPC UA" tab you can enable and edit the OPC UA
server function of the readers.
The "Network interfaces" tab
The "Network interfaces" tab contains the following area:
● Network ports
● SNMP
● NTP
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
to add new events. Click the button
Description of the events
Description
If an antenna error occurs on the selected antenna, the output changes to the
status specified here.
If a transponder is identified, the output is changed to the state specified here.
If the state at the selected digital input changes, the output is set to the state
specified here.
If the state at the selected digital output changes, the output is set to the state
specified here.
If the state at the selected PLC output changes, the physical output is set to
the state specified here.
RF680R/RF685R only
Configuring with the WBM
7.3 The menu items of the WBM
to remove already specified
71