Commissioning

Note
Commissioning the readers in PROFIBUS operation
You will find information on commissioning the RF680R and RF685R readers via a
communications module (PROFIBUS operation) in the manual of the relevant
communications module.
4.1

Important notes on using the device

Safety notices on the use of the device
The following safety notices must be adhered to when setting up and operating the device
and during all work relating to it such as installation, connecting up, replacing devices or
opening the device.
General notes
Safety extra low voltage
The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a
Limited Power Source (LPS). (This does not apply to 100 V ... 240 V devices.)
This means that only SELV / LPS complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1
must be connected to the power supply terminals. The power supply unit for the equipment
power supply must comply with NEC Class 2, as described by the National Electrical Code
(r) (ANSI / NFPA 70).
There is an additional requirement if devices are operated with a redundant power supply:
If the equipment is connected to a redundant power supply (two separate power supplies),
both must meet these requirements.
Opening the device
D not open the device when energized.
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
WARNING
WARNING
4
21