Siemens SIMATIC RF600 Series Configuration Manual page 11

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

List of available protocols
All available protocols and their ports that are used with SIMATIC RF600 readers are listed
below.
Table 2- 1
List of available protocols
Protocol
Port number
SSH
TCP/22
(OEM only)
XML service
TCP/10001
DHCP
UDP/68
PROFINET
UDP/34964
UDP/49152-65535
HTTP
TCP/80
HTTPS
TCP/443
NTP
UDP/123
SNMP
UDP/161
OPC UA
TCP/4840
Ethernet/IP
TCP/44818
UDP/44818
UDP/2222
Explanation of the table:
● Authentication
Specifies whether authentication of the communication partner takes place.
● Encryption
Specifies whether the transfer is encrypted.
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
Default port
Port configura-
status
ble
Open
--
Open
--
Closed
Open
Open
--
Closed
Closed
Closed
Open
Open
Security recommendations
Authentication
Encryption
Yes
Yes
No
No
No
No
No
No
No
No
Yes
Yes
No
No
No
No
Yes (simple,
No
when config-
ured)
No
No
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents