Siemens SIMATIC RF600 Series Configuration Manual page 77

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

Figure 7-15
Basic settings
In the "OPC UA" area you can make the basic settings for the OPC UA interface. Select the
"Enable" check box to enable the OPC UA interface.
Table 7- 19
Parameter
Application name
Default port
Minimum
sampling interval
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
The "Settings - Communication" menu item, "OPC UA" tab
Description of the parameters
Description
Name of the OPC UA application of the server. The application name is re-
quired to identify the OPC UA namespace of the reader and should be unique
for each reader within the project.
The application name is part of the URL of the OPC UA server of the reader.
Here you can change the port number of the application. As default, port num-
ber 4840 is used, the standard TCP port for the OPC UA binary protocol.
Minimum sampling interval at which the reader samples the process data. The
sampling interval is limited to a minimum value of 10 milliseconds,, to reserve
adequate time for other processes.
Range of values: 10 .. 50 ms
Default setting: 50 ms
Configuring with the WBM
7.3 The menu items of the WBM
77