Negative Xml Replies - Siemens SIMATIC RF600 Series Configuration Manual

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

10.3.4

Negative XML replies

If problems occur during the execution of the command, the reader reports this to the user
application. These error messages always include an event code ≠ 0 and information about
the problem.
Reply
<frame>
<reply>
</reply>
</frame>
Parameter
Parameter
value_id
value_resultCode
value_name
value_cause
List of possible result codes
Result code
hex
0x00
0x13
0x1A
0x91
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
<id> value_id </id>
<resultCode> value_resultCode </resultCode>
<error>
<name> value_name </name>
<cause> value_cause </cause>
</error>
Type
Decimal value
0...9
Decimal value
0...9
Text
Text
Name
dec
0
NO_ERROR
19
ERROR_MEMORY_OVERRUN
26
ERROR_TAG_LOCKED
145
ERROR_NO_ASWER_FROM_TAG
Values
Description
0...4294967295
Unique command identifier
0...65535
Identification number of the error
You will find a list of possible return
codes in the following table.
--
Textual description of the error
You will find descriptions of the prob-
lems in the following table.
--
Brief description of the cause of the
negative reply.
Description
Positive reply, command processed suc-
cessfully.
Access outside the addressed memory
area.
The transponder to which data is meant to
be written or which should be deactivated is
locked.
The transponder is not responding.
Programming via XML interface
10.3 XML commands
213

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents