Programming via XML interface
10.3 XML commands
Parameter
Parameter
value_id
value_iPAddress
value_
subNetMask
value_gateway
value_
dHCPEnable
10.3.2

Reader settings

This section describes all the commands with which you can control the configuration of the
reader.
10.3.2.1

setConfiguration

This command transfers a configuration to the reader. After confirming the configuration, this
is activated and stored permanently in the flash memory of the reader. To be able to work
with the newly created configuration, you need to restart the reader.
As an alternative, you can also load a configuration that was created using the WBM.
Note that the reply frame of the reader can take up to 20 seconds.
Command
<frame>
<cmd>
</cmd>
</frame>
150
Type
Decimal value
0...9
IP address
IP address
IP address
Fixed values
<id> value_id </id>
<setConfiguration>
<configData>
<![CDATA[value_configData]]>
</configData>
</setConfiguration>
Values
Description
0...4294967295
Unique command identifier
1.0.0.1...
IP address of the reader
255.255.255.254
Parameter is ignored, if DHCP is acti-
vated:
value_dHCPEnable = True
1.0.0.1...
Subnet mask of the reader
255.255.255.254
Parameter is ignored, if DHCP is acti-
vated:
value_dHCPEnable = True
1.0.0.1...
Gateway of the reader
255.255.255.254
Parameter is ignored, if DHCP is acti-
vated:
value_dHCPEnable = True
True
Use of DHCP to assign the IP address.
False