Getactiveconfiguration - Siemens SIMATIC RF600 Series Configuration Manual

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

Programming via XML interface
10.3 XML commands
10.3.2.4

getActiveConfiguration

This command requests the active parameters with which the reader is currently working as
a configuration file from the reader.
Note that the values may differ from the stored values.
Note that the reply frame of the reader can take up to 20 seconds.
Command
<frame>
<cmd>
</cmd>
</frame>
Reply
<frame>
<reply>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 213)".
154
<id> value_id </id>
<getActiveConfiguration/>
<id> value_id </id>
<resultCode> 0 </resultCode>
<getActiveConfiguration>
<returnValue>
<configID> value_configID </configID>
<configData>
<![CDATA[value_configData]]>
</configData>
</returnValue>
</getActiveConfiguration>
Configuration Manual, 11/2018, C79000-G8976-C386-07
SIMATIC RF600

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents