7.3 The menu items of the WBM
Device clock
The device time according to ISO 8601 (UTC), as well as the calculated local time, is displayed
in this area. With the "Synchronize with PC" button, you can synchronize the displayed local
time with the time in your operating system.
Note
The device time always corresponds to UTC time (ISO 8601)
Note that the device time always corresponds to UTC time (ISO 8601) and cannot be adapted to
time zones. Clicking the button transfers the local time stored in your operating system to the
WBM. Because the time synchronized with the PC is lost when the power supply is terminated,
we recommend synchronizing the time with an NTP server.
Configuration display
A diagram of the reader is shown to the right of the areas. The schematic diagram contains
information on the connected reader type. With the "Flash" check box, you can have the LEDs
of the reader flash. This enables you to quickly and easily identify the reader.
7.3.2

The "Settings - General" menu item

The "Settings - General" menu item is divided into the following areas:
• Log settings
• Service logbook settings
Figure 7-4
The "Settings - General" menu item
Log settings
In the "Log settings" area, you can use the check boxes to decide which events are entered in
the log. The log is structured as a ring buffer. Bear in mind that with a high degree of detail
42
Operating Instructions, 08/2023, C79000-G8976-C698-02
SIMATIC RF1100