Programming via XML interface
10.3 XML commands
Parameter
Parameter
value_id
value_inValue
value_outValue
10.3.2.13

resetReader

This command resets the reader.
After a positive reply from the user application, the reader terminates the TCP/IP connection
and then performs a reset. Following this, you need to establish the connection again with
the user application and restart with the "hostGreetings" command.
166
Type
Values
Decimal value
0...4294967295
0...9
Binary characters
0000....
0, 1
1111
Binary characters
0000....
0, 1
1111
Description
Unique command identifier
Each position stands for an input of the
reader:
Inport00: 1st position (least signifi-
cant bit right)
Inport01: 2nd position
Inport02: 3rd position
Inport03: 4th position
...
Depending on the value of the particu-
lar position, the corresponding input is
set to ON (1) or OFF (0).
If the reader does not support I/O the
value remains empty.
Each position stands for an output of
the reader:
Outport00: 1st position (least signif-
icant bit right)
Outport01: 2nd position
Outport02: 3rd position
Outport03: 4th position
...
Depending on the value of the particu-
lar position, the corresponding output is
set to ON (1) or OFF (0).
If the reader does not support I/O the
value remains empty.
Configuration Manual, 11/2018, C79000-G8976-C386-07