Extended Blocks; Config_Upload/-_Download - Siemens SIMATIC RF600 Series Configuration Manual

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

Programming via Rockwell controller
9.5 Programming add-on instructions
9.5.2

Extended blocks

9.5.2.1

Config_Upload/-_Download

Using the "Config_Upload" and "Config_Download" blocks, you can read out
("Config_Upload") or write ("Config_Download") the configuration of the RF680R/RF685R
readers via the control program.
The configuration data is not interpretable data. Save the data on the controller so that it can
be written to the reader again if a device is replaced. Bytes 6-9 (see table below) contain a
configuration ID with a unique version identifier. With the configuration ID, when performing a
"Config Upload", you can check whether the configuration data read matches the
configuration data stored on the controller. The configuration data has the following
structure:
Table 9- 7
Byte
0
2
6
10 ... "DATA" end
"Config_Upload/Config_Download" can be executed on every channel of the
RF680R/RF685R. It is always the same configuration data that is transferred.
Figure 9-7
118
Structure of the configuration data
Name
Structure identifier (2 bytes)
Length information (4 bytes)
Length of the version identifier and parameter block
Version identifier (4 bytes)
Based on the identifier, you can uniquely identify the configuration.
This is a time stamp in Linux format.
The time stamp indicates how many seconds have passed since Jan-
uary 1, 1979, 00:00 (midnight). The identifier is assigned when a con-
figuration is generated.
Parameter block
"Config_Upload" block
Configuration Manual, 11/2018, C79000-G8976-C386-07
SIMATIC RF600

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents