Siemens SIMATIC RF600 Series Configuration Manual page 219

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

Parameter
Value_
filterDataAvailable
value_fieldName
value_bank
value_
startAddress
value_dataLength
value_data
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
Type
Values
Fixed values
True
False
Text
--
--
0...3
Decimal value
0...65535
0...9
Decimal value
1...510
0...9
Hexadecimal
--
value
0...9, A...F
Programming via XML interface
10.4 XML EventReports
Description
Optional
Indicates whether or not a filter criteri-
on was received.
True:
No problem. All the data was read
or there was no filter set.
False:
Data could not be read.
Name of tag field
Is specified in the WBM (refer to the
section "The "Settings - Tag fields"
menu item (Page 63)").
Memory bank of the tag field
0: Reserved
1: EPC
2: TID
3: USER MEMORY
Start address of the first byte in the
memory bank where reading will start.
Number of bytes to be read.
Data that should be read. Each byte is
represented by two hexadecimal char-
acters.
Example:
The byte sequence "0x12, 0x34, 0xA3"
is represented as the character string
"1234A3" in the "value_data" parame-
ter.
"value_dataLength" is 3 in this exam-
ple.
If the transponder is identified but the
data cannot be read (e.g. if the tran-
sponder has no user memory as re-
quired), this field remains empty.
"value_success" is then set to "False".
219