10.3 XML commands
● The masking value specifies which action value bit is to be set as s/w as shown in the
table above ("skip/write" where "skip=0" and "write=1").
● The action value specifies which lock should be defined for each memory bank.
● The "r/w" flag locks the password for read and write access.
● The "w" flag locks the password for write access (read access permitted).
● The "p" flag specifies a permanent lock.
The following tables show possible combinations of the "r/w" and "w" flags with "p" flags and
the meaning of the combination for a memory bank.
The transponder is in the "open" status when it is identified and in the "secure" status when
its access password is verified.
Table 10- 3
w
0
0
1
1
Table 10- 4
r/w
0
0
1
1
208
Possible combinations of the "w" and "p" flags
p
Description
0
Write access to the particular memory bank is possible from both the "open" and
the "secure" status.
1
Write access to the particular memory bank is permanently possible from both the
"open" and the "secure" status, it cannot be locked.
0
Write access to the particular memory bank is possible from the "secure" status but
not from the "open" status.
1
No write access to the particular memory bank is possible.
Possible combinations of the "r/w" and "p" flags
p
Description
0
Read and write access to the particular password is possible from both the "open"
and the "secure" status.
1
Read and write access to the particular password is permanently possible from
both the "open" and the "secure" status, it cannot be locked.
0
Read and write access to the particular password is possible from the "secure"
status but not from the "open" status.
1
No read or write access to the particular memory bank is possible.