Hostgoodbye - Siemens SIMATIC RF600 Series Configuration Manual

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

Programming via XML interface
10.3 XML commands
Parameter
Parameter
value_id
value_readerType
value_version
value_configID
10.3.1.2

hostGoodbye

This command ends communication with the reader and terminates the TCP/IP connection.
In the default setting, the reader continues working with its current settings. This allows the
reader to work independently. The data accumulating when the reader is operating
independently is stored in the buffer - depending on the selected operating mode. You will
find further information on the buffer or on asynchronous notifications in the section
"Programming via XML interface (Page 137)".
Command
<frame>
<cmd>
</cmd>
</frame>
Reply
<frame>
<reply>
</reply>
</frame>
146
Type
Decimal value
0...9
Fixed values
Alphanumeric text
Alphanumeric text
<id> value_id </id>
<hostGoodbye/>
<id> value_id </id>
<resultCode> 0 </resultCode>
<hostGoodbye/>
Values
Description
0...4294967295
Unique command identifier
SIMATIC_RF680R
Optional
SIMATIC_RF685R
Reader type
SIMATIC_RF650R
If the connected reader does not match
the value specified,
SIMATIC_RF615R
"ERROR_PARAMETER_ILLEGAL_
VALUE" is returned.
If this parameter is not specified, the
connected reader type is not checked.
V2.1
Supported API protocol version
--
Unique identifier of the transferred
configuration.
The ID can also be read using the
"getConfigVersion" function.
Configuration Manual, 11/2018, C79000-G8976-C386-07