Xml Eventreports; Events; Tageventreport - Siemens SIMATIC RF600 Series Configuration Manual

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

Result code
hex
0xE7
0xE8
0xE9
0xEA
0xEB
0xFA7 4007
10.4

XML EventReports

This section describes all the frames that can be sent by the reader to the user application
(XML reports). The reports can be transferred reliably or without verification. You will find
more information on XML reports in the section "Functionality of the XML interface
(Page 137)".
10.4.1

Events

This section describes all events. Events are asynchronous messages sent by the reader
containing data acquired by the reader itself.
10.4.1.1

tagEventReport

A triggered read point acquires transponder data that is sent to the user application with a
tag event report.
The configuration of the trigger (continuous, I/O level, ...) and the definition of the
transponder data (tag fields, RSSI value, ...) to be sent are taken from the stored
configuration. These parameters cannot only be changed using the WBM.
The transponder data in every event report is grouped according to the read points.
A reply frame from the user application is necessary only when secure mode is set. A reply
frame can, however, also be sent in non-secure mode and this has no negative influence.
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
Name
dec
231
ERROR_READ_COMMAND_
FAILED
232
ERROR_WRITE_COMMAND_
FAILED
233
ERROR_WRITETAGID_COMMAND_
FAILED
234
ERROR_LOCK_COMMAND_
FAILED
235
ERROR_KILL_COMMAND_
FAILED
ERROR_READPOINT_NOT_FOUND
Programming via XML interface
10.4 XML EventReports
Description
The read command failed.
The write command failed.
Writing the EPC-ID failed.
The Lock command failed.
The Kill command failed.
The specified read point is inactive because
it was not assigned to any antenna.
215

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents