4 Connecting the router
The local console only displays
rubbish.
You have forgotten the access
password for the router.
Date and time in the device are
lost when restarted.
The LAN, WAN or SFP do not
light up in green.
The S LED is red.

4.6 Updating the software

The Regesta Smart PLC router can be updated to new releases. Please contact your distributor for further details on
new releases.
There are various ways to update one of our routers: For further information, please see manual Dm 748-I Software
Updating.
The software required to update one of our routers is supplied in a format known as distribution. This consists of a
single file, which contains all the files needed to update your device as well as in-depth information on the contents of
the files.
The Regesta Smart PLC incorporates independent modules for the Wireless WAN interface. You can pick modules
from different manufacturers or choose several modules from the same provider, depending on the technology used.
Generally, the firmware is independent from the device's software. There is an UPGRADE file for each Wireless
WAN module. Please ask you distributor for the correct UPGRADE file (according to the module in your device). The
manual describing the Cellular interface (Dm781-I) explains how to upgrade the module.
The Regesta Smart PLC also incorporates a PLC module, which need its own firmware. This PLC module can oper-
ate in several modes. To change operating mode, you usually need to change the PLC firmware. This firmware is in-
dependent of all other softwares in device. Please ask your distributor for the correct PLC UPGRADE file. The manu-
al describing the PLC Gateway (Dm 823-I) explains how to upgrade the module.
26
Check the terminal has the correct port configured.
Check the terminal configuration is 115200 8N1.
Check the console is not an events process.
Check the terminal has the correct port configured.
Check the terminal configuration is 115200 8N1.
Ignore the configuration through the RST button (as explained in the relevant sec-
tion).
Parameters configured through the time set command will be lost when the device
restarts. Use the NTP protocol to keep the date and time configuration.
Check the Ethernet cable, or Fiber, and the connection to the network (you may
need a crossover cable).
For further information, please see manual: "Teldat Dm709-I LAN Interfaces" .
Check the SIM card has been inserted correctly,
or
Check the SIM PIN is correct,
or
Check the antenna is properly installed (been screwed in correctly),
or
Get your technical service to check the device is in the optimum position for the
service.
For further information, please see manual: "Teldat Dm781-I Cellular Interface " .