Clutch Operation - Optional

The clutch is controlled by a toggle switch on the
Console. See Figure 2-16.
Clutch characteristics are as follows:
1. The clutch is engaged when power (12 volts) is
applied.
2. The seeder has provisions to mechanically lock the
clutch to drive the seed metering system, by aligning
the hole in the Clutch Shaft with the slot in the Clutch
Hub and securing with a 1/4 x 1-3/4 Bolt, Flat
Washers and Locknut. See Figure 3-16.
3. The clutch must be disengaged (power off) when
seed shafts are turned manually for calibration.
4. Check clutch operation: Clutch will engage when
power is applied. (Clutch will make a clicking sound).
Set seeder on the ground and drive a short distance
while turning switch on and off. The seed shaft will
stop rotating when switch is turned to "NO SEED"
position.
IMPORTANT
At no time use high pressure water or air to clean the
clutch as damage could occur.
Figure 3-16: Clutch Lock Bolt
F-1021-0719
Electronic Acre Meter Kit -
Optional
IMPORTANT
Acre Meter is dust and splash resistant, under no
circumstances should this unit be submerged in any
conductive, corrosive, or flammable liquid. At no
time use high pressure water or air to clean it, as this
can damage the unit.
Settings for Loup Acre Meters
The battery operated Acre Meter operates in one of two
modes.
1. In sleep mode, the display is blank, and the counter
is accumulating acres. Sleep mode will be entered if
a button is not pressed for 20 seconds.
2. In entry mode, the display is on, and the operator can
enter values. To get into entry mode, press the
*
/FUNC button. If you continue to press the
button, the acre counter will cycle through the
functions that it can perform. The LEDs above the
display indicate which function is selected.
The available functions are:
Field Acres, Total Acres, Pulses per 400 feet, Width,
Password and Low Battery
Field Acres
*
Press the
/FUNC button until the "FIELD" LED is lit.
The digits indicate the acres covered since the field acre
counter was cleared.
To clear the field acre count, press the UP and DOWN
buttons simultaneously for two seconds. If a password
has been entered, you will not be able to clear the total
acre count. Field acres will count in tenths of an acre up
to 9999.9 acres.
Total Acres
*
Press the
/FUNC button until the "FIELD" and "TOTAL"
LEDs are lit. The digits indicate the acres covered since
the total acre counter was cleared.
To clear the total acre count, press and hold the UP and
DOWN buttons for two seconds. If a password has been
entered, you will not be able to clear the total acre count.
Total acres will count from.1 to 99999 acres.
Pulses Per 400 Feet
*
Press the
/FUNC button until the "PULSES" LED is lit.
The number in the display indicates how many pulses are
generated for every 400 feet driven. There are two
methods to enter the pulses per 400 feet:
OPERATION
*
/FUNC
3-11