Seed Shaft Sensor Installation - Optional - Landoll Brillion SS16 Operator's Manual

Sure stand ag seeder
Hide thumbs Also See for Brillion SS16:
Table of Contents

Advertisement

ASSEMBLY
Seed Shaft Sensor Installation -
Optional
Contact dealer to order.
1. Install Spacer w/Magnet on the Right Seed Shaft
between first and second Seed Meters. See
Figure 2-13
2-16
Figure 2-13: Seed Shaft Sensor Installation - Optional
2. Install Sensor Bracket using Seed Meter existing
1/4-20 x 1 Machine Screws, Lock Washers and Nuts.
3. Install Seed Shaft Sensor onto Sensor Bracket.
4. After installation, seed meters need to be zeroed.
(See "Seed Rate Chart" on page 3-9.)