Device Configuration Interbus 2Mbit/S Foc; Led Indicators Interbus 2Mbit/S Foc - Leuze electronic DDLS 200 Series Original Operating Instructions

Bus-capable optical data transmission
Hide thumbs Also See for DDLS 200 Series:
Table of Contents

Advertisement

INTERBUS 2MBit/s FOC
Connection group
FOC bus ter-
minal
FOC
Incoming bus
Participant
Figure 7.2: Connection of the DDLS 200 to the INTERBUS (fiber-optic cable)
7.2

Device configuration INTERBUS 2MBit/s FOC

Changeover transmission rate (default: '2M')
In the DDLS 200, switch S2 must be used to specify in the transmission rate of the FOC INTERBUS:
Switch S2
Position 500k:
Position 2M (default):
Changeover incoming/outgoing bus (default: 'In Bus')
Switch S3 must be used to specify in the DDLS 200 whether the connected FOC is for the incoming
bus (In Bus) or outgoing bus (Out Bus):
Switch S3
Position In Bus (default):
Position Out Bus:
NOTE
The delay time of a light path is approx. 2.5 µs.
7.3

LED indicators INTERBUS 2MBit/s FOC

In addition to the indicators and operational controls present in all device models (bar graph, buttons,
LEDs AUT, MAN, ADJ; see chapter 11.1 "Indicators and operational controls"), the INTERBUS model
also has the following indicators:
30
Switch S3
Position In Bus
H1
H2
transmission rate 500 kBit/s.
transmission rate 2 MBit/s.
incoming bus FOC, outgoing bus optical data transmission.
incoming bus optical data transmission, outgoing bus FOC.
Switch S3
Position Out Bus
DDLS 200
Participant
H2
H1
Outgoing bus
Leuze electronic
FOC