Bus Transceiver And Device Supplied Via Separate Power Connection; Bus Transceiver Supplied Via Bus Cable, Device Supplied Via Separate Power Cable - Leuze electronic DDLS 200 Series Original Operating Instructions

Bus-capable optical data transmission
Hide thumbs Also See for DDLS 200 Series:
Table of Contents

Advertisement

9.1.1 Bus transceiver and device supplied via separate power connection

• Switch S2 = Vin.
• Bus electrically isolated (isolated node).
• CAN_GND must be connected to V-.
DeviceNet/CANopen
outgoing bus
DeviceNet/CANopen
incoming bus
Figure 9.2: Bus transceiver and device supplied via separate power connection

9.1.2 Bus transceiver supplied via bus cable, device supplied via separate power cable

• Switch S2 = BUS.
• Bus electrically isolated (isolated node).
DeviceNet/CANopen
outgoing bus
DeviceNet/CANopen
incoming bus
Figure 9.3: Bus transceiver supplied via bus cable, device supplied via separate power cable
Leuze electronic
Power
Power
DDLS 200
DeviceNet / CANopen
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents