Technical Data; General Technical Data - Leuze electronic DDLS 200 Series Original Operating Instructions

Bus-capable optical data transmission
Hide thumbs Also See for DDLS 200 Series:
Table of Contents

Advertisement

Technical data

3
Technical data
3.1

General technical data

Electrical data
Supply voltage Vin
Current consumption without optics
heating
Current consumption with optics
heating
Optical data
Operating range
Transmission diode
Opening angle
Ambient light
LED risk group
Input/output
Input
Output
Controls and indicators
Membrane keyboard
Individual LEDs
LED strip
Mechanical data
Housing
Weight
Degree of protection
8
18 ... 30VDC
Approx. 200 mA at 24 V DC (no load at switching output)
Approx. 800 mA at 24 V DC (no load at switching output)
0.2 ... 30m (DDLS 200/30...)
0.2 ... 80m (DDLS 200/80...)
0.2 ... 120m (DDLS 200/120...)
0.2 ... 200m (DDLS 200/200...)
0.2 ... 300m (DDLS 200/300...)
0.2 ... 500m (DDLS 200/500...)
Infrared light, wavelength 880 nm
± 0.5° with respect to the optical axis for 120m ... 500 m mod-
els,
± 1.0° with respect to the optical axis for 80 m models,
± 1.5° with respect to the optical axis for 30 m models
> 10000 Lux acc. to EN 60947-5-2:2008
Exempt group in acc. with EN 62471
0 ... 2VDC:
transmitter/receiver deactivated
18 ... 30VDC: transmitter/receiver activated
0 ... 2VDC:
normal operation
Vin ... 2VDC:
limited function reserve
Output current max. 100 mA, short-circuit proof, protected
against overvoltage, transients and overheating
Change of operating mode
Display of voltage supply, operating mode, data communica-
tion (dependent on type)
Bar graph indicator of the received signal level
Diecast aluminum; optical inlet/outlet, glass
Approx. 1200 g
IP 65 acc. to EN 60529:2000
DDLS 200
Leuze electronic