Wiring - Leuze electronic DDLS 200 Series Original Operating Instructions

Bus-capable optical data transmission
Hide thumbs Also See for DDLS 200 Series:
Table of Contents

Advertisement

Ethernet
10.4

Wiring

NOTE
As shown in figure 10.5 through 10.7, a distinction is to be made between a 1 : 1 cable and
a crossover cable. The crossover cable is required whenever the participants (switch, hub,
router, PC, PLC, etc.) connected to the DDLS 200 do not provide "autocrossing". If the
"autocrossing" function is available in the connected participants, a normal 1 : 1 cable can
be used.
DDLS 200 between switch/hub and end device/PLC
Switch / hub
1 : 1 cable
Figure 10.5: DDLS 200 between switch/hub and end device/PLC
NOTE
Make sure that the 1 : 1 cable or crossover cable are connected correctly.
Do not plug the 1 : 1 cable to the switch/hub into the "Uplink" port.
DDLS 200 between switch/hub and switch/hub
Switch / hub
1 : 1 cable
Figure 10.6: DDLS 200 between switch/hub and switch/hub
NOTE
Make sure that the 1 : 1 cable or crossover cable are connected correctly.
Do not plug the 1 : 1 cable to the switch/hub into the "Uplink" port.
54
Optical data transmission
Optical data transmission
DDLS 200
End device / PLC
Crossover cable
1 : 1 cable
Leuze electronic
Switch / hub