Commissioning / Operation (all device models)
11.2

Operating modes

The following table provides an overview of the DDLS 200 operating modes.
Operating
Description
mode
Automatic,
Normal operation
AUT LED illu-
minates
Manual,
Alignment mode,
MAN LED
switch-off threshold on higher
illuminates
level
Adjust,
Alignment mode,
ADJ LED illu-
switch-off threshold on higher
minates
level
Change of operating mode
AUT –> MAN Press the operating mode button for more than 2 seconds.
Only the device on which the button was pressed switches to the "Manual" operating
mode (MAN LED illuminates).
MAN –> ADJ Press the operating mode button on one of the two devices.
Both devices switch to the "Adjust" operating mode (both ADJ LEDs illuminate) when
both were previously in the "Manual" operating mode.
ADJ –> MAN Press the operating mode button on one of the two devices.
Both devices switch to the "Manual" operating mode (both MAN LEDs illuminate).
MAN –> AUT Press the operating mode button for more than 2 seconds.
Only the device on which the button was pressed switches to the "Automatic" operat-
ing mode (AUT LED illuminates).
NOTE
If, while in the AUT operating mode, the operating mode button is pressed for longer than
13s, the device switches to a special diagnostic mode. The AUT, MAN and ADJ LEDs illu-
minate simultaneously (see chapter 13.2 "Diagnostic mode" on page 64).
To switch to the "Adjust" (ADJ) operating mode, both devices belonging to a transmission
path must first be in the "Manual" (MAN) operating mode. It is not possible to switch directly
from the "Automatic" to the "Adjust" operating mode or vice versa.
62
Optical data
transmission
Active
Active
Disconnected
DDLS 200
Bar graph assignment
Its own receiving level,
Display of the alignment quality
of the opposing device
Its own receiving level,
Display of the alignment quality
of the opposing device
Received signal level of the
opposing device,
Display of the alignment quality
of own device