Electrical Connection Interbus 500Kbit/S - Leuze electronic DDLS 200 Series Original Operating Instructions

Bus-capable optical data transmission
Hide thumbs Also See for DDLS 200 Series:
Table of Contents

Advertisement

6
INTERBUS 500kBit/s / RS 422
The INTERBUS model of the DDLS 200 has the following features:
• Operating ranges 30m, 120m, 200m, 300m, for INTERBUS
• Electrically isolated interface
• The DDLS 200 is not an INTERBUS participant
• Protocol-independent data transmission, transparent compared to other RS 422 protocols
• 500kBit/s fixed transmission rate with INTERBUS,
with RS 422 generally lower transmission rates as well
• Operating range 500m for RS 422 up to 100kBit/s
• Cascading of several DDLS 200 is possible (see Chapter 4.3)
6.1

Electrical connection INTERBUS 500kBit/s

The electrical connection to the INTERBUS is made at terminals DO... / DI... and COM as shown in
Figure 6.1.
S4 S4
Bus
Bus
COM
COM
DI1 DI1
DI1 DI1
D01
D01
D01
D01
In In
COM
COM
D02
D02
D02
D02
DI2 DI2
DI2 DI2
Out
Out
COM Tx Tx– Tx+ Tx+ Rx Rx– Rx+ Rx+
COM
S1
Figure 6.1: Connection board of the INTERBUS model
ATTENTION!
Please be sure to observe the installation requirements (bus cables, cable lengths,
shielding, etc.) defined in the INTERBUS standard EN 50254
Leuze electronic
OUT
OUT
WARN PE PE GND
WARN
GND Vin
Vin
IN IN
PE PE GND
GND Vin
Vin
IN
Off
On
INTERBUS 500kBit/s / RS 422
INTERBUS - terminals and switches
Terminal
Function
DO1 / DI2, Rx+ Receiving line +
DO1 / DI2, Rx– Receiving line –
DI1 / DO2, Tx+ Transmission line +
DI1 / DO2, Tx– Transmission line –
COM
Potential equalization
Switch
Function
S4
Position In:
Position Out (default):
DDLS 200
incoming bus with
shielding connection
via RC element
outgoing bus with
direct shielding con-
nection
25