Led Indicators Interbus 500Kbit/S / Rs 422 - Leuze electronic DDLS 200 Series Original Operating Instructions

Bus-capable optical data transmission
Hide thumbs Also See for DDLS 200 Series:
Table of Contents

Advertisement

Device configuration RS 422
General RS 422 protocols can be transmitted with the DDLS 200. No baud rate setting is necessary
(max. 500kBit/s). The shielding connection can be set via switch S4 as with the INTERBUS.
NOTE
The delay time of a light path is approx. 1.5 µs (depending on the distance).
6.3

LED indicators INTERBUS 500kBit/s / RS 422

In addition to the indicators and operational controls present in all device models (bar graph, buttons,
LEDs AUT, MAN, ADJ; see chapter 11.1 "Indicators and operational controls"), the INTERBUS model
also has the following indicators:
PWR Tx
Rx
Figure 6.4: Indicators and operational controls of the INTERBUS model
Leuze electronic
LED PWR: green
green flashing= transmitter / receiver unit switched off
AUT
MAN
ADJ
off
LED Tx:
green
green flashing= with baud rates set to very low values,
off
LED Rx:
green
green flashing= with baud rates set to very low values,
off
DDLS 200
INTERBUS 500kBit/s / RS 422
= operation indicator
via switching input IN or hardware error
= no operating voltage
= data is being transmitted to the bus
the LEDs Tx and Rx flicker. At very
high baud rates (> 50kBit/s), flashing
LEDs Tx and Rx indicate faulty bus
communication.
= no data on the transmission line
= data is being received by the bus
the LEDs Tx and Rx flicker. At very
high baud rates (> 50kBit/s), flashing
LEDs Tx and Rx indicate faulty bus
communication.
= no data on the receiving line