Profibus Connection - Devices With M12 Connectors - Leuze electronic DDLS 200 Series Original Operating Instructions

Bus-capable optical data transmission
Hide thumbs Also See for DDLS 200 Series:
Table of Contents

Advertisement

PROFIBUS / RS 485
ATTENTION!
Please be sure to observe the installation requirements (bus cables, cable lengths,
shielding, etc.) defined in the PROFIBUS standard EN 50170 (Vol. 2)
5.2

PROFIBUS connection - devices with M12 connectors

The electrical connection of the PROFIBUS is easily performed using M12 connectors. Ready-made
connection cables are available as accessories both for connecting the incoming bus as well as for
connecting the continuing bus (see chapter 14 "Accessories").
For all M12 device models, the connection is made via the two left, B-coded connectors BUS IN and
BUS OUT (see Figure 5.2).
PROFIBUS: BUS IN
M12 connector, B-coded
Figure 5.2: Location and designation of the M12 PROFIBUS connections
BUS IN
A (N)
2
GNDP 3
4
NC
B (P)
M12 connector
(B-coded)
Figure 5.3: Assignment M12 connector BUS IN
22
PROFIBUS: BUS OUT
M12 socket, B-coded
BUS IN (5-pin M12 connector, B-coded)
Pin
1
2
3
NC
1
4
5
Thread
Name
NC
Not assigned
A (N)
Receive/transmit data A-line (N)
GNDP
Data reference potential
B (P)
Receive/transmit data B-line (P)
NC
Not assigned
FE
Functional earth (housing)
DDLS 200
All M12 device models: PWR IN
M12 connector, A-coded
Comment
Leuze electronic

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents