FLAP TRANSMISSION MOTOI
PIPER NAVAJO SERVICE MANUAL
C707
ADAPTER HOUSING
SPLINE
/
ASCERTAIN THAT SPLINE DRIVE IS
/
CENTERED IN THE ADAPTER HOUSING
MOUNTING NUTS
VIEW C
POINTER ATTACHED TO
TRANSMISSION FLEXIBLE
SHAFT (MAKE FROM 032
SAFETY WIRE)
REFERENCE MARK
SECURE ONE END OF MCTOR
WITH A TONGUE DEPRESSOR OR
SIMILAR METHOD
NOTE
USE CAUTION NOT TO
DAMAGE MOTOR SHAFT'
IF DISTANCE BETWEEN REFERENCE
--MARK AND POINTER EXCEEDS
5 32 OF AN INCH (4 MM) REPLACE
FLEXIBLE SHAFT ASSEMBLY
SKETCH 3
Figure 3-2a. Wing Flap Actuator Cable - 500 Hour Inspection
(cont.)
Added: 11/15/82
INSPECTION
1D16