Piper Navajo PA-31 Service Manual page 308

Table of Contents

Advertisement

PIPER NAVAJO SERVICE MANUAL
TABLE VI-II. LEADING PARTICULARS, HYDRAULIC POWER PACK (WIEBEL TOOL)
NOMENCLATURE
Operating Pressure
Main Relief Valve Pressure (Primary)
Hand Pump Relief Valve Pressure (Secondary)
Hand Pump Relief Valve Reseat Pressure
Low Pressure Thermal Relief Vent Valve "Open"
Low Pressure Thermal Relief Vent Valve "Closed"
Priority Valve Cracking Pressure
Hand Pump Check Valve Cracking Pressure
Landing Gear Position Release
Time Delay Valve
Hydraulic Fluid Required
Weight Dry - Power Pack
Hydraulic Fluid Flow Rate (Both Pumps Operating)
WTC 2135-1
1900 P.S.I.
1900 P.S.I.
2100 P.S.I. Max.
1900 P.S.I. Min.
0 to 100 P.S.I.
150 P.S.I. Max.
600 P.S.I.
1 to 3 P.S.I.
750-1250 P.S.I.
5 to 9 seconds
MIL-H-5606
10.50 pounds
1.6 G.P.M.
WTC 2135-3
1800 P.S.I.
1800 P.S.I.
2000 P.S.I. Max.
1800 P.S.I. Min.
Oto 100 P.S.I.
150 P.S.I. Max.
600 P.S.I.
1 to 3 P.S.I.
750-1250 P.S.I.
5 to 9 seconds
MIL-H-5606
10.50 pounds
1.6 G.P.M.
Reissued: 10/12/79
HYDRAULIC SYSTEM
2B2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Navajo pa-31-300Navajo pa-31-3

Table of Contents