PIPER NAVAJO SERVICE MANUAL
b.
With switch turned ON, connect voltmeter
as shown in Step 2, Figure 11-12.
Make sure positive (+) and negative (-) voltmeter
leads are connected as shown.
c.
If meter
reads
battery voltage,
disconnect
lead at alternator
"F1" (field)
terminal.
1. If reading is still battery voltage, wiring is not defective,
and no more
wiring tests need be made.
2.
If voltage
reading
is zero, the "NEG" and "FLD" leads are reversed.
Circuit trace will be burned open between points A-A, B-B, or C-C, Figure 11-14.
d. If meter
reads
zero voltage,
disconnect
lead at alternator
"F1" (Field)
terminal,
and connect
a jumper
lead from this lead to battery positive (+) post.
See Figure
11-13.
1. If meter
now reads
battery
voltage,
the "POS" and "FLD" leads are
reversed.
This misconnection
alone will not cause the circuit
trace to be burned
open.
2.
If meter
now reads
backwards,
alternator
field terminal
is connected
to regulator
negative
terminal,
the positive
line is connected to regulator
field
terminal,
and regulator
positive terminal
is connected to negative side of circuit.
Either the circuit trace will be burned between points C-C, D-D, or E-E, Figure
11-14, or the driver
transistor
will be open. In either case, the driver bias re-
sistor will have been overheated.
e.
If voltmeter
reads
backwards,
disconnect
lead at alternator
"F1" (Field)
terminal.
1. If meter
still reads
backwards,
the "POS" and "NEG" leads are
re-
versed.
The circuit
trace
may be burned between points C-C, D-D, E-Eor
F-F,
Figure
11-14.
The transient
suppression
diode will always be open or shorted.
2.
If meter
now reads
zero, the positive
line is connected to regulator
"NEG"terminal,
the negative line is connected to the regulator
"FLD" terminal,
and the alternator
"F1" (Field)terminal
is connected to the regulator
"POS" ter-
minal.
The circuit
trace will be burned open between points F-F, Figure
11-14.
For further assistance, follow the procedure in the
latest revision of DELCO-REMY Service Bulletin
IR-273 when troubleshooting circuits containing
this regulator.
Revised: 9/24/81