C453
C453
OHMMETER
TYPICAL
BATTERY
HARNESS
CONNECTOR
NEG.
POS.
JUMPER
LEAD
2
VOLTMETER
Figure
11-12.
Volt-Ohmmeter
Test
Figure
11-13.
Jumper Connection
11-21.
REGULATOR(DELCO-REMY)
11-22.
CHECKING REGULATOR CIRCUIT.
Regulator failures
may be caused
by circuit
misconnections,
such as reversed
leads or shorting
or grounding of
terminals
with a screwdriver,
etc.
The following provides a means of locating
circuit
misconnections.
It also covers
the different
types of regulator
panel
board circuit
trace defects which indicate a certain
type of wiring harness
mis-
connections.
A burned circuit
trace on the regulator
panel board is proof that a
circuit
misconnection
exists,
or occurred
at some time.
However,
a miscon-
nection
will not always cause a burned circuit trace even though circuit
compo-
nent failures
have been caused.
Before installing
a new regulator,
it is very important
tomake
sure that no
wiring
circuit
defects
or wiring
harness
misconnections
exist.
If the wiring
harness
is defective,
or if misconnections
exist, the new regulator
will fail too.
Furthermore,
repeated
replacement
of regulators
will only result
in repeated
regulator
failures,
and this will continue until the circuit defect is corrected.
To check the wiring harness
for defects or misconnections
before install-
ing the new regulator,
observe
the following procedure:
NOTE
Meter connections
are made to the harness
connector
that has been unplugged from the regulator.
Reissued: 10/12/79